SFP+ 100GB Singlemode SM 40km

 

PRODUCT SFP, XFP, QSFP, SFPS (SFP+)
SPEED ET (100M), G1 (1GB), G2 (2GB), G5 (5GB), G6 (6GB), GX (10GB), G2X (20GB), G4X (40GB), GXX (100GB)
TYPE RJ (RJ45), SM (Single-mode), MM (Multimode), BIDI (Bi-Directional), WDM, DDMI, DWDM, CWDM
DISTANCE 100 (100m), 300 (300m), 500 (500m), 2 (2km), 10 (10km), 20 (20km), 40 (40km), 80 (80km), 120 (120km)
CODING TYPE CIS (Cisco), HP, JP (Juniper), EX (Extreme), Leave empty if no coding
Təhlükəsiz alış-veriş
  • Visa Card
  • MasterCard
  • PayPal
  • Apple Pay

Tətbiq sahəsi

 

  • 100G Datacom& Telecom connections
  • 100Gbase-ER4

Texniki

 

Parameter Symbol Min. Typ. Max Unit Notes
Transmitter
Data Rate DR 4*25.78125 GBd
Data Rate Variation DRV -100 +100 ppm
Modulation Format NRZ
Wavelength L0 WL0 1294.53 1295.56 1296.59 nm
Wavelength L1 WL1 1299.02 1300.05 1301.09 nm
Wavelength L2 WL2 1303.54 1304.58 1305.63 nm
Wavelength L3 WL3 1308.09 1309.14 1310.19 nm
Total Launch Power Ptotal 8.9 dBm
Average Optical Launch Power Per Lane Pout -2.9 2.9 dBm 1
Power Optical modulation amplitude per lane POMA 0.1 4.5 dBm 2
Extinction Ratio ER 8 dB
Side-mode suppression ratio SMSR 30 dB
Launch power of OFF
Transmitter per lane -30 dBm
Eye Mask IEEE 802.3 Clause 88
100Gbase-ER4,
{0.25, 0.4, 0.45, 0.25, 0.28, 0.4}
Optical Return Loss Tolerance ORLT 20 dB
Transmitter reflectance TR -12 dB 3
Receiver
Data Rate DR 4*25.78125 GBd
Data Rate Variation DRV -100 +100 ppm
Modulation format NRZ
Wavelength L0 WL0 1294.53 1295.56 1296.59 nm
Wavelength L1 WL1 1299.02 1300.05 1301.09 nm
Wavelength L2 WL2 1303.54 1304.58 1305.63 nm
Wavelength L3 WL3 1308.09 1309.14 1310.19 nm
Damage Threshold for Receiver per lane Pdamage 5.5 dBm 4
Average receiver power Rpow -20.9 -3.5 dBm 5
Receiver sensitivity per lane (OMA) -21.4 dBm 5
Receiver Reflectance RXR -26 dB
LOS assert per lane LOSA -27 dBm
LOS de-assert per lane LOSD -24 dBm
LOS Hysteresis 5 dB

Notes
1. Power-on Initialization Time is the time from when the power supply voltages reach and remain above the minimum recommended operating supply voltages to the time when the module is fully functional.
2. The single ended input voltage tolerance is the allowable range of the instantaneous input signals.

Məlumat cədvəli