Fiber Optik Patch Kordlar – Armoured – FULLX

 

TYPE CPR (CPRI), FXS (FULLX), IPX (IPFX), NSN (NSN), WPR (Waterproof)
CONNECTOR TYPE A ST, SC, MU, LC, FC, E2
CONNECTOR TYPE B ST, SC, MU, LC, FC, E2
CAPACITY SX Simplex, DX Duplex
FIBRE TYPE A1 (G657A1), A2 (G657A2), B3 (G657B3), M1 (OM1), M2 (OM2), M3 (OM3), M4 (OM4), M5 (OM5), S2 (OS2)
CABLE COLOUR BLK, WHT
ARMOURING AM Armoured, Blank
LENGTH (M) 1, 2, 3, 4, 5, 10, 15, 20, 100
MATERIAL H (High Density Polyethylene), L (LSZH), E (PE), P (PVC)

 

Təhlükəsiz alış-veriş
  • Visa Card
  • MasterCard
  • PayPal
  • Apple Pay

Tətbiq sahəsi

 

  • Multi-purpose outdoor
  • For the connection between the distribution box and RRH
  • Deployment in remote radio head cell tower applications

Texniki

Connector Types

Type Reference Conformance Note
LC IEC 61754-20 Single-mode duplex

Multimode duplex

APC: Green connectors, green boots
UPC: Blue connectors, white bootsUPC: Grey Connectors, white boots

 

Patch Cord Versions

Jumper Tolerance Requirement
Overall Length (L) (M) Length of Tolerance (CM)
0<L≤20 +10/-0
20<L≤40 +15/-0
L>40 +0.5%L/-0

 

Mechanical Characteristics

Test Conditions Reference
Endurance 500 matings IEC 61300-2-2
Vibration Frequency: 10 to 55Hz, Amplitude: 0.75mm IEC 61300-2-1
Cable Retention 400N (main cable); 50N (ranch part) IEC 61300-2-4
Strength of Coupling Mechanism 80N for 2 to 3mm cable IEC 61300-2-6
Cable Torsion 15N for 2 to 3mm cable IEC 61300-2-5
Fall 10 drops, 1m drop height IEC 61300-2-12
Static Lateral Load 1N for 1h (main cable); 0.2N for 5min (ranch part) IEC 61300-2-42
Cold -25°C, 96h duration IEC 61300-2-17
Dry Heat +70°C, 96h duration IEC 61300-2-18
Change of Temperature -25°C to +70°C, 12 cycles IEC 61300-2-22
Humidity +40°C at 93%, 96h duration IEC 61300-2-19

 

Optical Characteristics

Parameter Reference
Single Mode Multimode
Insertion Loss Typical value ≤0.15dB; Maximum ≤0.30 Typical value ≤ 0.15dB; Maximum ≤0.30 IEC 61300-3-34
Return Loss ≥60dB (APC); ≥50dB (UPC) ≥ 30dB (UPC) IEC 61300-3-6

 

End-Face Geometry

Item UPC (Ref: IEC 61755-3-1) APC (Ref: IEC 61755-3-2)
Radius of Curvature (mm) 7 to 25 5 to 12
Fibre Height (nm) -100 to 100 -100 to 100
Apex Offset (μm) 0 to 50 0 to 50
APC Angle (°) / 8° ±0.2°
Key Error (°) / 0.2° max

 

End-Face Quality (Single-Mode)

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 25 None None IEC 61300-3-35:2015
B: Cladding 25 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of Ferrule None None

 

End-Face Quality (Multimode)

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 65 None None IEC 61300-3-35:2015
B: Cladding 65 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of Ferrule None None

Məlumat cədvəli